本文介绍了贵阳电厂化学车间排水、主厂房排水和煤厂排水的水质及处理试验结果.提出了将化学车间废水用于锅炉冲灰系统后排至灰场、煤厂废水经石灰处理后达标排放、主厂房废水经混凝-气浮除油处理后用做冷却水的污水治理与回用方案.
The quality and treatment experiments of wastewaters drained from the generating house, chemical shop and coal yard of Guiyang power plant in Guizhou Province, Southwest China were studied. A wastewater disposal and reuse programme has been proposed as follow: the wastewater from generating house is treated by coagulation and floatation to remove oil and then reused as cooling water; the water from chemical shop utilized for ash flushing and finally discharged to ash field and the water from coal yard treated by lime to meet the discharge standard and discharged.