本文通过对XRF水冷却外循环系统的技术改造,解决了因停水而被迫停机的问题。大大地提高了XRF的工作效率,对保护设备起到了较大的作用,结果令人满意。同时。
In this paper, by means of the technical trasformation of the water cooling external circulatory system of XRF,the problem of having to stop machint caused by cutting off the water supply was solved. It greatly improves the working efficiency of XRF was (largely raised) and played a very important role in protecting the equipments. The (satisfactory) result of determination was obtained. Meantime, the working principle of this system is introduced.
出处
《光谱实验室》
CAS
CSCD
1994年第3期13-15,共3页
Chinese Journal of Spectroscopy Laboratory
关键词
外循环系统
设计
荧光光谱仪
X射线
External Circulatory System, Quantometer, Water Level Controller,XRF, Internal Temperature Control