摘要
用电加热方式对新型自补偿γ量热计进行了刻度,测量了低功率反应堆的K11孔道和7号孔道内不锈钢的γ释热率。在相同γ释热条件下,使γ释热率的测量误差由没刻度时的±8.0%减小到±1.0%。
A new self-compensation gamma thermometer has been calibrated by means of electric heating.The gamma heat rate in the low POwer reactor(LPR) has also been measured successfully.Comparing with measurements without calibration,the measurement error of gamma heat rate at 1 W of gamma heat is reduced from ±8.0% to ±1.0%.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
1994年第3期271-275,共5页
Nuclear Power Engineering
关键词
γ量热计
低功率堆
热量计
刻度
New type self-compensation gamma thermometer Calibration of out-ofcore LPR Gamma heat rate