摘要
采用CR-39固体径迹探测器,根据辐射损伤密度沿粒子的径迹分布规律,测定了经3、4cm空气降能和φ1mm孔准直的α粒子(5.15MeV)的Bragg峰位。对于通过3cm空气后能量降至~12MeV的α粒子,在CR-39中的Bragg峰位大约在7μm深度处,理论计算值在6.14μm,实验值与理论值符合得较好。
sing a CR-39 solid track detector the Bragg peak location for 239Pu α-particles (5.15MeV) passing through an air gap of 3 or 4cm and a collimater of φ1mm aperture is determined according to the distribution rule of radiation damage density along charged particle tracks. For a-particles of about 1.2MeV, the Bragg peaks in CR-39 are located at about 7 μm, and the calculated value in this case is 6.14 μm. The experimental result is in good agreement with the theoretical value.