摘要
简要介绍了QUICK格式及其精度,推导了三维QUICK格式的系数及其假扩散系数,并将QUICK格式应用于大型W型火焰电站锅炉三维冷态炉内流场的数值计算,计算结果能反映炉内流动的基本特征.
Ih this paper, the QUICK scheme and its precision is concisely presented, the three-dimensional QUICK scheme coefficient and its false diffusion coefficient are derived, the QUICK scheme is applied to the numerical calculations of the three-dimensional cold-state flows in the large W-shape flame power boilers. the calculation resuit is able to show the basic characters of flows in the boiler.
关键词
锅炉
数值计算
控制容积法
稳定性
QUICK scheme
large power boilers
three-dimensional flow
cold-state flow
numerical calculations