本文在开式功率流机械传动试验台上对DISCO型无级变速器进行了效率试验。通过试验研究了该类无级变速器空载功率损失和传动效率的变化趋势,并对提高传动效率的途径进行了讨论。
On the open-powr mechanicla drive test bed,DISCO mechanical stepless variator was tested,Fromthese experiments. we research the changing tendency of its unloaded power lase and transmission effiiency.On the same tune,the way of raising transmission efficiency was discussed in this peper