二次风罩降低燃具NO_X的研究李铮(建设部标准定额研究所,北京100000)傅忠诚(北京建筑工程学院,北京100044)张尊中(北京公用事业科研所,北京100000)1问题的提出NOX包括NO和NO2,其毒性远远超过CO。NO和血色素的亲和力约为CO?..
The statistical analysis of the experimental data indicates that the different position and amount of secondary air supplied can affect the discharging level of NOX from gas cookers, and that NOX is formed easily provided the secondary air enters reaction zones through flame roats. In this paper, we have also made research on the geometric factors of secondary air shad (SAS) in order to decrease NoX and CO emission, Simultaneously,we have given the theoretical explanation for the results. We reacned the conclusion that SAS is feasible and NoX reducing is effective.
出处
《煤气与热力》
北大核心
1994年第1期22-27,共6页
Gas & Heat