期刊文献+

日本产温室设施的性能测定 被引量:3

Performance Measurement of the Greenhouse Facilities Imported From Japan
下载PDF
导出
摘要 通过对日本产温室的测试研究,对其结构特性,覆盖材料及配套设施包括室内外遮阴帘,双层保温幕,通风及降温系统,自动控制系统的性能等进行了分析,提出了改进意见。 Through measuring and studying the greenhouse imported from Japan, this paper discussed the structure characteristics of the greenhouse. It explained how the ridge window and side window affect the environmental factors in concrete terms, compared the heat effect in the greenhouse covered by MMA double sheet with that covered by glass, compared the sunshade effect of shading curtain in the greenhouse with that over the greenhouse, analysed the effect of cooling greenhouse by fog and fan system, and finally confirmed the degree of automation achieved in the greenhouse operation controlled by computer. It was thought that the main defect of the fog and fan system was that the droplet cann't be evaporated completely and there was some water left on the ground. This paper also presented that the effect of heat preservation was not very well by using the double thermal insulation curtain. The curtain had some disadventages, such as, the film' s life was too short and so on.
作者 徐刚毅
出处 《农业工程学报》 EI CAS CSCD 北大核心 1994年第3期156-160,共5页 Transactions of the Chinese Society of Agricultural Engineering
关键词 温室 设施 环境控制 性能 测定 Greenhouse Installation Environmental control