摘要
介绍了堆泵浦 ̄3He-Ar-xe激光实验中放大管的设计及混合气的组成。经聚乙烯慢化体慢化后的CFER-H脉冲堆的热中子注量率为6×10~(14)n/cm ̄2·s,根据慢化体结构设计了内充气体组份为 ̄3He:Ar:Xe=34.7:34.7:0.267,6oomm×Φ34mm的放大管,在约1.4×10 ̄(16)裂变每脉冲下进行 ̄3He-Ar-Xe(λ=1.73μm)激光激射实验,获得毫瓦级功率输出。
The Iaser cell configuration and gas compositions used in reactor pumped  ̄3He-Ar-Xe lasing experiments are presented.The thermal neutron flux of CFBR-Ⅱ reactor, surrounded by high-density polyethylene to moderate the pulse of fastueutrons,is 6×10~(14)n/cm ̄2·s. According to the structure of polyethylene,the gas compositions is , ̄3He:Ar:Xe=34.7: 34.7: 0.267, 6oomm×Φ34mm(KPa)and the laser cell is Φ 34mm×600mm.The output power is of the level of milliwatts in the first lasing test of reactor pumped  ̄3He-Ar-Xe(λ=1.73μm).
出处
《强激光与粒子束》
EI
CAS
CSCD
1994年第3期461-464,共4页
High Power Laser and Particle Beams
基金
国家高琳激光技术领域资助项目
关键词
激光
放大管
反应堆抽运
氦3
Reactor pumped laser  ̄3He-Ar-Xe system, laser cell