摘要
本文讨论了汽轮机低真空供热热负荷、变工况计算、热化系数、热网供回水温度等问题。提出对居民小区,最佳热化系数为0.53—0,55.而且与热网供回水温度的确定无关,可供工程设计时参考。
This peper discusses the issues concerning the computation of steam turbine low-vacuum heat supplythermal loads, off-design performance, thermification factors,heat supply network feeding and re turn water temperstures,etc. The author Proposed that the optimum thermification factor should be0.53-0. 55 irrespective of the network feedins and return water temperatures,which can be taken asa reference value for engineering designs.
出处
《热能动力工程》
CAS
CSCD
北大核心
1994年第1期32-36,共5页
Journal of Engineering for Thermal Energy and Power
关键词
热电联产
热力网
供热
供电
ogeneration,heat netuork,heat supply