摘要
本文就煤气公司化肥贮配站出口水封的振动问题进行了详细的现场振动实测,并应用“结构的工作振动形态分析法”,对采集的数据进行了处理,其处理结果以动画结构显示,提出了解决水封振动的方案,最终解决了水封的振动问题。
According to the structural stroboscopy.the author made a derailed testing of vibration cf the exit water-seal body used in Coal-Gas Company fertilizer storage station,and analysed and handled the testing data.The results have been displayed the structural vibrating shape by cartoon.A.plan of resolving water-seal body vibration has been drawn up as well.and the problem would be settled at last.
关键词
故障诊断
煤气储罐
出口
水封体
operational vibration shape,fault diagnosis,structure