摘要 人或牛血清白蛋白溶液调至pH10并在4℃左右放置30h,诱导出重复性良好的极谱峰。然后把试样溶液调至适当pH并记录极谱电流。在浓度低于1.0×10-5mol/L时,峰电流对浓度作图是直线,试样浓度可从图上直接读出。对影响白蛋白测定的诸因素作了详细研究和讨论。结果对富含硫的蛋白质的极谱研究有参考价值。 After the human or bovine serum albumin solution was adjusted to pH 10 and stood for 30h at around 4℃, a reproduceable polarographic peak is induced. Then,the sample solutions were adjusted to suitable pH, and the peak currents were recorded. When the concentrations are lower than 1. 0×10-5mol/L, the plot of peak currents versus concentration is a straight line, so that sample solution concentration can be read directly from the graph. The factors of influence on the polarographic determination were investigated and discussed in detail. The results may throw a light on the polarographic study of sulphur rich proteins.
机构地区 南开大学化学系
出处 《生物化学杂志》 CAS CSCD 1994年第5期553-556,共4页
基金 国家自然科学基金
关键词 极谱 血清清蛋白 测定 Human serum albumin Bovine serum albumin Polarography