摘要
用过氧化氢-甲基红体系催化分光光度法测定油品中的痕量铁,建立了轻油消化的操作方法。轻、重油品分别经消化、灰化后可直接测定。摩尔吸收系数为5.8×10 ̄5L(cm·mol) ̄-1,最低检测限为0.05μg/25ml,加标回收率为99.3%-102.5%。该法不受其他微量元素的干扰,操作简单,选择性好,灵敏度高。
The method is based on the principle that Fe(Ⅲ)can catalyze the decolorizing reactionwhich results from the oxidation of methyl red by hydrogen peroxide in dilute H_2SO_4nedium.Digestion conditions of light petroleum products are inspected.Light or heavyietroleum products are directly determined after digestion or ashing.The molar absorptivityis 5.8 × l0 ̄5L·cm ̄-1·mol ̄-1,with detection limit of 0.05μg/25ml and recovery of 99.3%-102.5%。The method has been used for determining trace iron in petroleum products withsatisfactory resuIts。
出处
《石油化工》
CAS
CSCD
北大核心
1994年第10期673-676,共4页
Petrochemical Technology
关键词
催化
分光光度法
石油产品
测定
catalytic spectrophotometry,trace iron,petroleum products