摘要
提出了一种比较简便的分光总日射表的校准方法。只要知道总日射表的正常灵敏度以及无色光学玻璃(WG295)滤光罩的滤光因子FF’和有色光学玻璃滤光罩的滤光因子FF'x,就可以通过修正因子Ax=FF’/FFx进行修正。得出带相应有色光学玻璃滤光罩的总日射表的灵敏度。特别强调了FFx'为存在内罩情况下测得的外罩的滤光因子,而不是一般意义下的滤光片的滤光因子FPx,二者在数值上是不等的。
simple calibration method of spectral pyranometers is described in this paper. Once the sensitivity of pyranometer. the filter factor FF' of clear spectral glass (WG 295)dome and the filter factor FF'x of color spectral glass dome are known. then the corresponding sensitivity of pyranometer with color spectral filter dome can be obtained by multiplying a modification factox Ax It is emphasized that the filter factor FF'x of the external dome but not the general filter factor FFx is measured when an internal dome exists. These two factors are not equal.
出处
《太阳能学报》
EI
CAS
CSCD
北大核心
1994年第4期391-394,共4页
Acta Energiae Solaris Sinica
关键词
分光总日射表
校准
滤光因子
spectral pyranometers, calibration, filter factor