摘要
根据有源逆变原理,将UPS设备老化负载由原电阻器换为有源逆变器,可将原发热浪费的能量转换成交流电能回馈到电网,获得再生利用,达到节能的目的,本文给出了老化节能负载装置的有关原理、电路结构和控制方法,可供用户开发成新的节能产品。
Based on the principles of active invert,the resistor used as the load ofUPS aging is substituted by active invert.By this way,the energy wasted by resistorbefore can be transformed into AC power fed back to network. So the energy canbe reused. The paper introduces the principles of this equipment,the circuit dia-gram and the controlling techniques.It enable users to develop thenew products of saving energy。
出处
《天津理工学院学报》
1994年第1期67-76,共10页
Journal of Tianjin Institute of Technology
关键词
不停电电源
节能
老化试验
电路
power semiconductor circuit active invert energy saving load used for UPS aging