摘要
对锅炉三级过热器、二级再热器吹灰器附近管段管壁冲刷减薄损伤进行了原因分析,并且采取相应对策,解决了吹灰器附近受热面管排过度冲刷问题,保证了锅炉正常运行。
The thinning of boiler third level supperheater tubes and second level reheater tubes around long-sootblowers were analyzed,several countermeasures were taken,then tube problem due to over-erode was solved,It ensures two boilers operating in good condition.
出处
《山西电力》
2005年第1期8-10,共3页
Shanxi Electric Power