摘要
根据12500kVA硅铁电炉循环水冷系统的运行情况分析了水垢形成的原因,提出了化学除垢的方案及工艺流程。实践证明,用化学清洗除垢切实可行,除垢率达到90%以上。
Abstract Formation reason of incrustation is analysed according to the operation of circulating water-cool system for 12500kVA ferrosilicon furnace.Plan of chemical contaminant separation and flowsheet are presented.practice shows that chemical cleaning method is workable,the rate of cleaning contaminanthas reached over 90%.
出处
《铁合金》
北大核心
1994年第1期57-59,40,共4页
Ferro-alloys