摘要 进行了电火工品瞬态脉冲试验,利用电热响应曲线计算了电火工品桥丝的温升,根据温升大小将电火工品分组进行升降法试验和发火试验。升降法试验表明温升较大组的电火工品 50%发火电流较低,t检验结果表明这 2组电火工品的 50%发火电流有显著差异。发火试验结果说明,在相同的试验电流下,温升较大组的电火工品发火个数较温升小的多。2项试验结果表明,温升大的组感度较高,说明瞬态脉冲试验是一种可对电火工品进行感度分类的方法。 The transient pulse testing is employed to evaluate the sensitivity performance of electro-explosive devices (EEDs) . The temperature rises of bridgewire are calculated according to the thermal responce curve of EEDs . The EEDs are classified into several groups according to the temperature rise. The up and down method is used to estimate the 50% firing currents of the EEDs that are sampled from the groups having different ranges of temperature rise. The experimental result shows that the 50% firing current of the group with higher temperature rises is lower, and t -analysis presents there is notable difference between 50% firing currents of the two groups. The firing test also shows the firing amount of EEDs having higher temperature rises is more than that having lower temperature rises when the current of firing test is the same. The results show that the higher the temperature rise is, the more sensitive the EED is,and it is feasible to use transient pulse testing for sensitivity classification of electro-explosive devices.
出处 《南京理工大学学报》 EI CAS CSCD 北大核心 2005年第1期52-54,共3页 Journal of Nanjing University of Science and Technology
关键词 电火工品 瞬态脉冲试验 电热响应 感度 electro-explosive devices transient pulse test electro-thermal response sensitivity
  • 相关文献

参考文献6

  • 1胡学先 朱玉.用无损试验技术对电点火器进行感度分类的新方法.兵工学报(火化工分册),1985,(3):1-5.
  • 2胡学先,胡轶.电火工品的感度控制和预报[J].火工品,1999(2):39-42. 被引量:5
  • 3艾鲁群.国外火工品手册(药剂和试验)[R].北京:国家机械委员会兵器标准化研究所,1988..
  • 4Ayres J N. The outlook for nondestructive electrothermal parametric measurements on wire-bridge EED's [A]. Proceeding of the 5th Symposium on Electroexplosive Devices [C]. Phila: The Franklin Institute, 1967.4-1.14-4-1.22.
  • 5Chretien N. Transient thermal testing of an electroexplosive bridgewire detonator [A]. Steering Committee. Proceeding of the 7th Int Pyrotechnics Seminar [C]. Chicago: IIT Research Institute, 1980. 94-106.
  • 6Rosenthal L A. Electrothermal Characteristic of Electroexplosive Devices [A]. Proceeding of 7th Symposium on Electroexplosive Devices [C].Phila: The Franklin Institute, 1971.24-1-24-15.