报告用国产磁分离法药盒的-TSH(IRMA)、M-FT_(3)、M-FT_(4)(RIA)测定正常人TSH62例,FT_3及FT_4各109例,其均值分别为2.57±1.16mIU/1、3.761±1.53pmol/l及17.10±4.41pmol/1。测定甲亢61例、甲减55例,其TSH、FT_3及FT_4均值分别为0.25±0.09mIU/1、16.41±5.08pmol/1、49.57+14.93pmol/l及17.24±l3.82mIU/1、1.12+0.48pmol/1、5.04±2.45pmol/1。还分别测定了44例低T_3综合症TT_3、TT-4及TSH、FT_3、FT_4在血循中的水平,并加以讨论。认为TSH、FT_3、FT_4检测对提高甲状腺疾病临床诊断的准确率有重要价值。
sTSH(IRMA)and FT_3,FT_4(RIA)kits which were made in China Institute of Atomic Energy areused tO measure serum TSH,FT_3 ,FT_4 concentrations in171 normal subjects.The mean values are2.57±1.16 mIU/1,3.76±1.53 pmol/l and l 7.1±4.4 l pmol/l respectively.61 hyperthyroid and55 hypothyroid patients are measured ,too. Their mean values of TSH,FT_3 and FT_4 are 0.25±0.09mIU/1,16.41±5.08 pmol/1.49. 57±14.93 pmol/1;17.24 ± l3.82 mIU/1,1.12l± 0.48pmol/1,5.04土2. 45 pmol/l respectively. Furthermore,sTSH,FT_3 and FT_4 are detected and dis-cussed in the 44 nonthyroid ilInesses(NTI).All of TT_3 mean values for NTI are less than those of nor-mal subjects,so this kind of diseases is named low T_3 syndrome.The study deems that sTSH,FT_3 andFT_4 tests are very important and valuable in the diagnosis and differential diagnosis Of thyroid diseasesand NTI.