摘要 介绍了HL 2A装置真空系统研制。它由真空主抽气系统、抽气偏滤器、直流辉光放电清洗系统组成。主抽气系统提供了装置真空室从大气到高真空、烘烤除气、直流辉光放电清洗所需要的抽气能力。抽气偏滤器初步实现了托卡马克放电过程中边缘粒子的抽运与控制;直流辉光放电清洗系统保证了装置良好的真空器壁条件。介绍了这些系统的初步运行情况,并给出了其测试结果。HL 2A装置首轮物理实验运行时真空室极限真空度达到4.6×10-6Pa,12h总漏放气率为1.8×10-5Pa·m3·s-1。 The basic design of a reliable vacuum system for the HL-2A tokamak is presented. It consists of the main pumping system, pumping divertor and glow discharge cleaning (GDC) system. The main pumping system provides the pumping capability for the high vacuum of chamber, outgassing by baking and GDC. The pumping divertor initially realizes the pumping and control of edge particles in tokamak discharge. The GDC system ensures the good wall condition of the device. The preliminary operation and the data obtained with these systems are also presented. The base pressure is 4.6 × 10-6 Pa, in the preliminary physical experiment operation of the HL-2A tokamak, and the total leak and outgassing rates of vacuum chamber is below 1.8 × 10-5 Pa·m3·s-1 in 12 hours.
出处 《核聚变与等离子体物理》 EI CAS CSCD 北大核心 2005年第1期59-64,共6页 Nuclear Fusion and Plasma Physics
关键词 HL-2A装置 偏滤器 直流辉光放电 托卡马克装置 真空室 真空系统 放电过程 粒子 物理实验 条件 Main pumping systerm Pumping divertor GDC Total leak & outgassing rate
  • 相关文献

参考文献7

  • 1Schneider U, the ASDEX Team. Ten year of operating experience with ASDEX [A]. Fusion Techn., Vol. 1 [C]. 1992.742.
  • 2Langley R A, Lamarche P. Vacuum pumping requirement considerations for future fusion devices [J] .J. Nucl. Mater.,1993,200:326.
  • 3Deites, Goetz G. Large turbomolecular pumps for fusion research and high-energy physics [J]. Vacuum, 1982,32( 10 -11) :703.
  • 4Ogiwara N, Anti T, Shimizu M. JT-60 Torus vacuum pumping system [A]. Fusion Techn. ,Vol. 1 [C]. 1984.381.
  • 5Poschenrleder W, Staudenmaier G, Staib P. Conditioning of ASDEX by glow discharge [J] .J.Nuel.Mater. ,1980,93/94:322.
  • 6Bosch H S, Coster D, Hass B G, et al. Particle exhaust studies in ASDEX Upgrade [ J ]. Plasma Phys. & Contr. Fusion,1997,39:1771.
  • 7Ageladarakis P, Papasteggiou S, stark D.The model & experimental basis for the design parametem of the JET divertor cryopump protection system including variations in divertor geometry & first wail materials [A]. Fusion Techn., Vol. 1[C]. 1996.431.

同被引文献33

  • 1王明旭,李波,杨志刚,严龙文,张年满,廖志清,严东海,郭建军.HL-2A装置偏滤器室中性气体压强规[J].核聚变与等离子体物理,2005,25(1):65-68. 被引量:4
  • 2朱毓坤,王明旭,孙守祁,肖正贵,李国栋,张年满,严东海.HL-1真空室的运行状态分析[J].核聚变与等离子体物理,1995,15(3):30-36. 被引量:2
  • 3程亚丽,鲍立曼,宋云涛,姚达毛.EAST超导托卡马克核聚变实验装置真空室窗口烘烤及热应力分析[J].原子能科学技术,2006,40(5):595-598. 被引量:10
  • 4王旭,臧义,徐彬,林家泉.基于开关管的级联H桥逆变器故障处理方法[J].中国电机工程学报,2007,27(7):76-81. 被引量:13
  • 5WINKEL T,HEMMERICH J L Helium Leak Detection in JET in The Presence of High Deuterium Partial Pressure[J]. J Vac Sci Technol, 1987, AS : 2637-2640.
  • 6KEEN B E. JET PROGRESS REPORT 1994[M]. Abingdon, UK: JET Publications Group of JET Joint Undertaking, 1995.67-68.
  • 7KEEN B E. JET PROGRESS REPORT 1997[M]. Abingdon, UK: JET Publications Group of JET Joint Undertaking, 1998.56-58.
  • 8朱毓坤 严东海 房开金 等.荧光检漏技术—聚变装置真空内衬的检漏[J].真空技术,1980,9(3):19-26.
  • 9中国核工业总公司成都核材料元件无损检测中心,朱毓坤.泄漏检测,第九章:大容器的检漏技术[M].成都:中国核动力研究设计院出版,1994.7.126—150.
  • 10中国核工业总公司成都核材料元件无损检测中心,朱毓坤.泄漏检测,第八章:四极质谱计在检漏技术中的应用[M].成都:中国核动力研究设计院出版,1994.7.114-125.

引证文献5

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部