介绍了大唐保定热电厂#8、#9炉冷渣器因结焦造成堵塞的情况,分析了结焦原因,阐述了防止结焦的措施及达到的效果。
This paper introduces how the slagcoolers of boilers No.8 and 9 of Baoding Cogeneration Power Plant, Datang Power Generation Co., are blocked due to clinkering, and why it occurred, and expounds measures taken to protect the two boilers from clinkering, which has reached satisfactory effect.
出处
《河北电力技术》
2005年第1期29-29,48,共2页
Hebei Electric Power
关键词
循环流化床
冷渣器
结焦
床温
床压
circulating fluidized bed
slagcooler clinkering
bed temperature
bed pressure