期刊文献+

小型锅炉水煤浆燃后电除尘的试验研究

Experiment on Electrostatic Precipitator for a Small Boiler Fueled by Coal-Water Slurry
下载PDF
导出
摘要 针对0.1t/h小型燃水煤浆热水锅炉设计和制作了前加旋风分离器的组合管式电除尘器单元试验装置,模拟了水煤浆燃后烟气的工况条件,进行了负载阳电晕的试验与检测.结果表明,在高压电场前加旋风分离器起到了预除尘和辅助荷电的作用,使电除尘性能有了显著地提高,在阳电晕17kV条件下,其除尘效率可达99.73%.燃常规水煤浆出口排放浓度20mg/m3,燃精细水煤浆出口排放浓度5mg/m3,大大优于国家的排放标准<80mg/m3.为研制小型燃水煤浆锅炉用的小型高性能电除尘器提供了较为可靠的依据. Based on a small boiler of 0.1 t/h capacity, a combined tubular electrostatic precipitator with an added-on air cyclone was designed to simulate the working condition of flue gas from coal slurry combustion. Operation of the test rig with an anodic corona were conducted and related measurement and analyses were taken. The air cyclone installed before the high-potential field acts as a pre-collector, making the performance of precipitator be remarkably improved. With anodic corona on 17 kV, the dust collection efficiency amounted to 99.73%. For fly ash from conventional slurry combustion, the solid concentration in emitted gas is 20 mg/m^3,and from ultra-clean coal slurry, 5 mg/m^3, both of them being much less than that of national stundard: <80 mg/m^3. Reliable technical basis is given for development and fabrication of high-efficient electrostatic precipitator for small boiler.
出处 《中国矿业大学学报》 EI CAS CSCD 北大核心 2005年第2期188-193,共6页 Journal of China University of Mining & Technology
关键词 水煤浆 高性能 旋风分离器 电除尘器 工况条件 排放浓度 荷电 小型锅炉 炉水 热水锅炉 small capacity boiler coal-water slurry electrostatic precipitator anodic corona dust collection efficiency
  • 相关文献

参考文献4

  • 1GB13271—2001.锅炉大气污染物排放标准[S].[S].,..
  • 2郝凤印.水煤浆系统技术[M].北京:中国洁净煤技术之四[M].,1998..
  • 3解广润 陈慈萱.高压静电收尘[M].北京:水利电力出版社,1993..
  • 4WhiteHJ 王成霞译.工业电收尘[M].北京:冶金工业出版社,1986..

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部