摘要
空气中磷化氢采集在内衬铝箔的复合膜袋中,取1ml注入气相色谱仪,经GDX-101柱分离后,火焰光度检测器检测。样品浓度为0.2~10.6mg/m3时,测定的RSD为4.0%~9.1%。样品在铝箔袋中保存,浓度可保持一周不变。本方法经辽宁省劳动卫生研究所验证,结果基本一致。
Air samples were collected in gas sampling bags made of aluminum and polyester and brought to the laboratory for analysis.1 ml of the sample was injected into a gas chromatograph equipped with a flame-photometric detector.A glass column (1m×3mm i.d.) packed with 40~60 mesh GDX 101 was used.Relative standard variations were in the range of 4.0%~9.1%for phosphine levels from 0.2~10.6mg/m3.Phosphine concentration was kept stable for a week when samples were stored in the bags. This method was verified by Liaoning provincial institute of occupational health.The results obtained were similar to the above.
出处
《卫生研究》
CAS
CSCD
北大核心
1994年第2期65-67,共3页
Journal of Hygiene Research