期刊文献+

HABR反应器常温下处理生活污水运行特性 被引量:2

Research on the Operational Characteristics of HABR in the Treatment of Domestic Sewage
下载PDF
导出
摘要 研究了在HABR反应器中水力停留时间、有机容积负荷、温度等操作参数对去除生活污水中 COD和 SS效率的影响,并做了灵敏度分析。结果表明:水力停留时间的缩短、温度的下降和 COD容积负荷的提高均会使COD去除率下降,但各操作参数影响反应器COD去除率的显著性不同,HRT是系统运行过程中需严格控制的关键性因素。 A pilot plant experiment of hybrid anaerobic baffled reactor(HABR) treating domestic sewage was presented in the paper and the influence of operation parameters on COD removal efficiency was studied. A sensitivity analysis was also performed for the operation parameters. The results showed that short HRT, low temperature and high organic loading rate could make the COD removal efficiency dropped. But the effects of the parameters were different. HRT was the key factor for the HABR.
出处 《安全与环境工程》 CAS 2005年第1期46-49,共4页 Safety and Environmental Engineering
关键词 HABR反应器 生活污水 运行特性 HABR domestic sewage operational characteristic
  • 相关文献

参考文献4

  • 1Lettinga, G.,J.Field, G. Zeeman,et al. Advanced anaerobic wastewater treatment in the future[J].Wat.Sci.Tech.,1997,36(10):5-12.
  • 2Barber, W. P. The use of the anaerobic baffled reactor (ABR) for wastewater treatment: a review[J].Wat.Res.,1999,33 (7):1559-1578.
  • 3Vieira, S.M.Anaerobic Treatment of Domestic Sewage in Brazil Research Results and Full-scale Experience[M].Oxford: Anaerobic Digestion, Pergamon Press(中译本).1988.136-144.
  • 4Nachaiyasit, S., D. C. Stucky. Effect of low temperature on the performance of an anaerobic baffled reactor(ABR)[J].Chem.Tech.Biotech.,1997,69(2):276-284.