摘要 在自行设计的电磁抗垢实验装置上,对热态工况下低频电磁抗垢(EAF)技术进行了实验考察。结果表明,在外加交变电磁场的情况下,总传热系数及污垢热阻发生了明显的变化,实验结束时污垢热阻下降了61%。不同的电磁场频率导致不同的抗垢效果,在本实验条件下,频率为700Hz时抗垢效果最佳。其他条件不变时,污垢热阻随着水质硬度的降低而减小,且不同流体硬度时污垢热阻的变化趋势均相同。对污垢晶体扫描电镜观察表明,经交变电磁场处理过的污垢晶体结构发生了明显的变化,由致密型易结垢的霰石变为松散型不易结垢的方解石,从而达到抗垢的目的,这一结论与冷态实验研究的结论一致。 The low frequency electromagnetic anti-fouling(EAF) technology was discussed on the basis of the experiment device devised by ourselves in the situation of heat state.The experiment shows that the changes of heat transfer coefficient and heat resistance of scale are very salient using EAF.The resistance reduced by 61 percent at the end of experiment.When the frequency changed,the effect of EAF was distinct, and the effect was the best when the frequency of magnetic field was 700 Hz.Under the same experimental condition but the liquid hardness changed,fouling resistance reduced along with the experimental liquid hardness decreasing. The observation of scale specimen through a scanning electron microscope indicated that the structure of fouling crystal changed. The hard and dense aragonite was changed into incompact calcite by EAF.The conclusion was consistent with the past experimental results.
作者 邢晓凯 马重芳 陈永昌 常宝英 王焱 陈小砖 Xing, Xiao-Kai; Ma, Chong-Fang; Chen, Yong-Chang; Chang, Bao-Ying; Wang, Yan; Chen, Xiao-Zhuan
出处 《石油大学学报(自然科学版)》 EI CSCD 北大核心 2005年第1期79-83,共5页 Journal of the University of Petroleum,China(Edition of Natural Science)
基金 国家'973'重大课题资助项目(G2000026304)
关键词 实验研究 效果 处理 扫描电镜观察 变化趋势 降低 实验条件 强化传热技术 污垢热阻 交变电磁场 heat state low frequency electromagnetic anti-fouling fouling crystal heat resistance of scale enhanced heat transfer scanning electron microscope
  • 相关文献

参考文献2

二级参考文献1

  • 1杨善让 徐志明.换热设备的污垢与对策[M].北京:科学出版社,1997.165-172.

共引文献5

同被引文献65

引证文献7

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部