摘要
压水堆发生失水事故时,从喷放开始到发生临界热流密度CHF这一段时间称为临界时间tCHF·tCHF决定了安全保护系统必须投入的时间,因此正确计算tCHF非常重要,论文分析了Griffith方法的缺点,作了较大的改进,经与实验值比较,改进方法所得的tCHF值与实验值吻合较好。
The critical time is the period from the instant at which the blowdown occurs to the in-stant when the critical heat flux(CHF)happens. It determines the time of operating thesafety protection system when a LOCA occurs in PWR. It is important to calculate the criti-cal time correctly. The weakness of Griffith′s method is analyzed and a great improvement isdeveloped in this paper. The critical time calculated by the improved method agrees with theexperimental values.
出处
《西安交通大学学报》
EI
CAS
CSCD
北大核心
1994年第6期43-49,共7页
Journal of Xi'an Jiaotong University