摘要
对不同管排数及不同翅片间距的9个三角形波纹翅片管换热器试件进行了传热与阻力特性试验,给出了实验特性曲线及关联式,并对管排数及翅片间距的影响规律进行了分析讨论,得出了有益的结果,另外,对三角形波纹翅片与平直翅片的结果进行了比较。
Air-side heat transfer and pressure drop performances of nine triangular wavy fin-and-tube heatexchanger coils were experimentally investigated.The Nusselt number and friction factor correlationswere provided in a wide range of Reynolds number.The results revealed the effects of fin space andthe number of tube rows on heat transfer and pressure drop.In addition,the present results were com-pared with those of plain plate fin and triangular wavy fin heat exchanger surfaces in the literature.
出处
《西安交通大学学报》
EI
CAS
CSCD
北大核心
1994年第2期77-84,共8页
Journal of Xi'an Jiaotong University
基金
机械电子工业部科学技术基金资助课题
关键词
换热器
翅片管
对流换热
热工设备
heat exchanger triangular wavy fin convective heat transfer