摘要
对电容式发爆器串联电爆网络准爆条件中的供电时间和最小发火电流的取值问题,进行了研究分析,提出将3个准爆条件用条件组来表达,以利现场应用,确保电爆网路的安全准爆。
The value fetch problems of supply electricity time and minimum lighting current of firing condition in series firing of capacitor blasting machine are analysed.It is suggested that the three firing conditions may be expressed with a set of conditions so as to use in the field conyeniently for ensuring safe tiring of blasting network.
出处
《西安矿业学院学报》
北大核心
1994年第2期134-138,共5页
Journal of Xi'an University of Science & Technology
关键词
电容式发爆器
准爆条件
电起爆
capacitor blasting machine
firing condition
firing current