期刊文献+

太阳能热泵的有限时间热力学分析 被引量:4

Finte-Time Thermodynamic Analysis of a Solar Heat Pump
下载PDF
导出
摘要 基于内可逆三热源热泵的有限时间热力学理论和太阳能集热器的线性热损模型,研究太阳能热泵系统的优化性能,导出太阳能集热器的最佳工作温度、系统的最大总性能系数和最大泵热率,并指出现有文献中有关这类研究的错误,所得结果可为实际太阳能热泵系统的优化设计提供一些新的理论依据。 The optimal performance of a solar heat pump system is investigated onthe basis of the finite-time thermodynamic theory of endoreversible three-heat-source heatpumps and the linear heat loss model of solar collectors. The optimal operating temperatureof the solar collector,and the maxima of the total coefficient of performance and the rate ofpuniping heat of the system are derived.Some errors,which are relative to the investigationof solar thermodynamic cycles and appear in the current literature,are pointed out.The re-sults obtained here can provide some new theoretical bases for the optimal design of the prac-tical solar heat pump system.
出处 《厦门大学学报(自然科学版)》 CAS CSCD 北大核心 1994年第3期333-338,共6页 Journal of Xiamen University:Natural Science
关键词 热力学 太阳能热泵 集热器 Finite-time thermodynamics,Solar heat pump,Collector,Optimal de-sign
  • 相关文献

参考文献7

  • 1陈金灿,J Appl Phys,1992年,72卷,3778页
  • 2曹水,太阳能学报,1992年,13卷,1期,59页
  • 3严子浚,太阳能学报,1992年,13卷,2期,207页
  • 4陈林根,孙丰瑞,陈文振.太阳能动力装置集热器最佳工作温度[J].太阳能学报,1991,12(2):191-195. 被引量:10
  • 5陈金灿,J Chem Phys,1989年,90卷,9期,4951页
  • 6陈金灿,Phys Rev A,1989年,39卷,8期,4140页
  • 7严子浚,科学通报,1987年,32卷,1280页

二级参考文献8

共引文献9

同被引文献30

引证文献4

二级引证文献23