摘要
用高盐雾化器(BabingtonNebulizer)作为氢化发生装置与电感耦合等离子体原子发射光谱(ICP/AES)结合同时测定氢化发生元素As、Sb、Se的分析方法,研究了在该氢化发生体系中共存过渡元素对以上元素的氢化发生的干扰及光谱干扰情况,评价了该法的检出限及多次测定的重现性,并用该装置测定了标准沉积物样品中As、Sb、Se的含量.
High salt nebulizer(Babington nebulizer)had been applied as a hydridegeneration device. The characteristics of the device was evaluated with the measurements ofAs,Sb,Se detectionm limits and the repeatabities for the mult-measurements. The detectionlimits of As,Sb,Se were 0.2,0.3 and 0.6 hg/ml,respctively. The interferences from thetransition metals on the hytlride generation of those elements were investigated.The systemdeveloped in the present work had been applied to the analysis of standard sediment samples.
出处
《厦门大学学报(自然科学版)》
CSCD
北大核心
1994年第3期359-363,共5页
Journal of Xiamen University:Natural Science
基金
国家自然科学基金
关键词
氢化发生技术
高盐雾化器
ICP-AES
Hydride generation
High salt nebulizer
As
Sb
Se in sediment sam-ples
ICP-AES