摘要
Based on the implementary project of the power supply main circuit on HL-2A, in order to make use of the old equipments and save money, the two old HL-1M OH power supply 5. 6 MVA pulsed transformers will be used in the E2, E3, E4 power supply after being reconstructed. As follows are the reconstructed design and analyze calculation.