摘要
介绍电液变阻起动器的结构设计、性能特点、工作原理及系统构成 ,详细介绍了电液变阻起动过程的可编程控制技术。与其他传统的降压起动方式相比 ,该系统由于在起动过程中两极板的距离均匀缩短 ,阻值线性降低 。
The paper recommends the construction feature, performance, working principle and system construction of electrolyte rheostat starter, describes in detail the programmable control technology used in soft starting with electrolyte rheostat. Compared with traditional voltage reducing starting up, the system has a very good soft feature, because of the distance uniformly shortened between two pole plates and the resistance reduced linearly during starting up.
出处
《有色设备》
2004年第6期18-20,共3页
Nonferrous Metallurgical Equipment
关键词
电解液变阻器
动极板
静极板
软起动
PLC
Electrolyte rheostat
Movable plate electrode
Static plate electrode
Soft start-up
PLC