期刊文献+

不同厂家安定片的体外溶出度比较

Comparison of the Dissolution of Diazepam Tablets
原文传递
导出
摘要 不同厂家安定片的体外溶出度比较裴云萍,葛卫红,李建平(南京市鼓楼医院药剂科,南京210008)摘要采用转篮法研究了四个厂家6个批号安定片的体外溶出度,实验数据用威布尔分布模型拟合,求得T_d、T_(50)、m.结果表明:不同厂家生产的安定片溶出度差异... Dissolution of six batches of diazepam tablets from four pharmaceutical ftctorleswas studied by the rotating basket method. Td, T50 and M were calculated by Weibulldistribution. We did not find a significant difference of the dissolution rates between variou.betches from the same factory but a great difference among the batches from different factories.
出处 《现代应用药学》 CSCD 1994年第2期39-40,共2页
关键词 安定片 溶出度 威布尔 分布模型 Diazepam tablets Dissolution rate Weibull distribution