期刊文献+

PPy/PMo_(12)膜修饰电极用于水体中化学需氧量测定的研究 被引量:2

Study on the detection of the COD values of the water by using PPy/PMo_(12) film modified electrode
下载PDF
导出
摘要 该文利用电化学方法制备了聚吡咯掺杂磷钼杂多酸(PPy/PM_(o12))膜修饰电极,该修饰电极对溶液中的 BrO_3^-有很好的电流响应。纳米 TiO_2-KBrO_3,共存体系可以光催化氧化水体中的有机物,体系中的 BrO_3^-浓度变化可用制备的修饰电极进行测定,继而建立了一种利用 PPy/PM_(o12)膜修饰电极测定水体中化学需氧量(COD)的新方法。实验中以葡萄糖为标准物质,研究了测定机理,优化了测定条件。实验结果表明,该方法操作条件温和,能实现快速、准确的测定。COD 值在50.0~500.0mg·L^(-1)浓度范围内,与修饰电极上的电流响应信号值成线性关系,检测限为25.0mg·L^(-1)。将该方法用于实际水样的检测,测定结果与 COD 标准分析法有好的一致性。 A new method of detection the chemical oxygen demand (COD) value using a PPy/PMo film modified electrode was described. The PPy/PMo_(12) film modified electrode was prepared with phosphomolybdate (PMo_(12))-doped polypyrrole(PPy) film by chemical syntheses on a glassy carbon electrode.The PPy/PMo_(12) film modified electrode showed high electrocatalytic activity toward the reduction of BrO_3^- and thus could be used as an amperometric sensor for the determination of the BrO_3^-.The photocatalytie and oxidation system,nano TiO_2-KBrO_3 co-existed system could degrade the organic compounds in water.The optimal experimental conditions and the mechanism of the detection were discussed by using glucose as a standard substance.The application range is 50.0~500.0 mg·L^(-1) and the lowest limit of detection is 25.0 mg·L^(-1).
出处 《化学传感器》 CAS 2005年第1期21-27,共7页 Chemical Sensors
基金 国家自然科学基金(No.20327001)资助课题
关键词 膜修饰电极 BrO3^- 电流响应 标准分析 磷钼杂多酸 线性关系 掺杂 化学需氧量 水体 COD PPy/PMo_(12) film modified electrode nano-TiO_2 COD(chemical oxygen demand) KBrO_3
  • 相关文献

参考文献7

  • 1金利通,刘彤,孙星炎,方禹之.磷钼杂多酸修饰电极催化还原测定IO_3^-与BrO_3^-的液相色谱电化学研究[J].分析化学,1993,21(10):1117-1121. 被引量:24
  • 2Keita B, Bouaziz D, Nadjn L. Strategies for entrapping oxometalates in polymeric matrices [J] . J Electroanal Chem, 1988, 255:307-313.
  • 3Hermann J M, Guillard C, Piehat P. Heterogeneous photocatalysls : an emerging technology for water treatment[J]. Catalysis Today, 1993, 17( 1 - 2): 7 - 20.
  • 4Heintz O, Robert D, Weber J V. Comparison of the Degradation of Benzaalide and Acetic Acid on Different TiO2 photoeatalysts[J]. J Photoehem Photobiol A: Chem,2000, 135:77 - 80.
  • 5H X Fu, G X Lu, S B Li. Adsorption and photo - induced reduction of Cr(VI) ion in Cr(VI) -4CP(4-chlorophenol) aqueous system in the presence of TiO2 as photocatalyst[J] . J Photochem Photobiol A: Chem,1998, 114:81 -88.
  • 6Cuesta A, Todoli J L, Mora J, et al. Rapid determination of chemical oxygen demand by a semi - automated method based on microwave sample digestion, chromium(VI) organic solvent extraction and flame atomic absorpti on sp ectrometry [J]. Anal Chim Acta, 1998, 372:399 - 409.
  • 7国家环保局编.水和污水监测分析方法(第三版)[M].北京:中国环境出版社,1998.354-357.

二级参考文献3

共引文献23

同被引文献31

  • 1谢振伟,于红,但德忠,王斌,丁桑岚.电化学法直接快速测定COD初步研究[J].环境工程,2004,22(3):60-63. 被引量:23
  • 2朱俊杰,胡娟,郑建斌,高鸿.示波电位滴定法测定COD的研究[J].分析科学学报,1994,10(3):44-47. 被引量:14
  • 3袁洪志.COD的极谱法研究[J].环境科学与技术,1994(2):26-28. 被引量:19
  • 4Pleskov Y V.Electrochemistry of diamond:a review[J].Russian Jonrnal of Electrochemistry.2002,38(12):1275.
  • 5Paw T N,Fujishima A.Recent advances in electrochemistry of diamond[J].Diamond and RelatedMaterials.2000,9(3-6):384.
  • 6Kraft A.Doped diamond:a compact review on a new,wersatile electrode material[J].InternationalJournal ofElectrochemical Science.2007,2(5):355.
  • 7刘梅川,赵国华,雷燕竹,唐轶婷.掺硼金刚石膜电极-流动注射技术快速直接测定水体COD的方法研究.第四届全国环境化学学术大会论文集(上册)[M].北京:中国环境科学出版社,2006.
  • 8Hermann J M,Guillsrd C,Pichat P.Hetemgeneous photocatalysis:all emerging technology for water treatment[J].Catalysis Today,1993,17(1-2):7.
  • 9H X Fu,G X Lu,S B Li.Adsorption and photo-induced reduction of Cr(VI)ion in Cr(VI)-4CP(4-chlorophen01)aqueous system in the presence of TiO2 as photocatalyst[J].J Photochem Photobiol A:Chem,1998.114:81.
  • 10Huijun Zhao,Dianlu Jiang,Shanqing Zhang.Kylie Cartetall.and Richard John.Development of a direct photoelectrochemical method for determination of chemical oxygen demand[J].Anal.Chem,2004.76:87.

引证文献2

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部