凝汽器空冷区铜管汽侧氨腐蚀研究 被引量:10

AMMONIA CORROSION OF COPPER TUBES IN AIR REMOVAL SECTION IN CONDENSER FOR POWER PLANT
下载PDF
导出
摘要 在 16种浓度的氨溶液 (从 5 0mg/L~ 2 0 0 0 0mg/L不等 )、3种温度 (2 5℃、35℃、4 5℃ )、3种溶解氧的条件下(开口、密闭不除氧、密闭除氧 ) ,对铜管腐蚀过程及影响氨腐蚀过程的因素及规律进行了研究 .结果表明 :氨腐蚀的主要因素为溶氧量、氨浓度、温度 ;尤其以溶氧量影响最大 ,使氨腐蚀的速度随着氧浓度的增加而加快 .最后提出了几种防止氨腐蚀的措施 . To simulate ammonia corrosion process of copper tubes in the air removal section of condenser in power plant,immersion tests of copper tube samples are conducted in ammonia solutions with ammonia 50~20000 mg/L,at temperatures 25℃、35℃ and 45℃ respectively.The tests conditions include:in open atmosphere,in a closed vessel and in deaerated solutions respectively.It is found that ammonia corrosion was mainly affected by the above three factors,especially the concentration of dissolved oxygen,which can influence the ammonia corrosion process greatly.The paper also introduced several preventive measures,which was valuable for engineering practice.
机构地区 长沙理工大学
出处 《腐蚀科学与防护技术》 CAS CSCD 北大核心 2005年第2期101-103,共3页 Corrosion Science and Protection Technology
基金 湖南省教育厅科研资助项目 (0 2C0 68) 湖南省自然科学基金资助项目 (0 1JJY3 0 2 7)
关键词 氨腐蚀 凝汽器 除氧 铜管 空冷 溶解氧 氧浓度 冷区 腐蚀过程 开口 condenser copper tubes ammonia corrosion weight-loss method
  • 相关文献

参考文献5

二级参考文献27

  • 1朱志平.锌基牺牲阳极特性探讨[J].腐蚀与防护,1995,16(1):31-32. 被引量:5
  • 2唐汉文.凝汽器冷却水的泄漏与胶封[J].中国电力,1995,28(6):31-33. 被引量:2
  • 3朱志平.间歇式阴极保护法的试验研究[J].腐蚀与防护,1996,17(4):150-153. 被引量:3
  • 4-.化学工程手册[M].化学工业出版社,1989(5).21-250,376,373.
  • 5窦照英.电力工业的腐蚀与防护[M].北京:化学工业出版社,1995..
  • 6周国定.热力设备金属腐蚀与防护[M].上海电力学院,1986..
  • 7窦昭英.电力工业的腐蚀与防护[M].化学工业出版社,1995..
  • 8武汉水利电力大学.热力发电厂水处理(下册)[M].水利电力出版社,1977..
  • 9西安热工研究所.热工技术手册(电厂化学)[M].北京:水利电力出版社,1993..
  • 10龚洵洁.热力设备的腐蚀与防腐[M].北京:中国电力出版社,1998..

共引文献22

同被引文献49

引证文献10

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部