摘要 采用自组装技术,将 5′端标记有巯基的 20-merODN(oligo 1)以金 硫键形式牢固结合在 7. 995MHz的AT-切石英晶体的镀金表面,然后由石英晶体微天平实时检测了与碱基序列互补的 10 merODN (oligo 2)和 8 merODN(oligo 3)的杂交,同时还研究了稀土金属铈离子在温和条件下对DNA的水解切断作用.结果表明:应用QCM方法可能实时检测DNA的固定和杂交,Ce(IV)能随机切断单链DNA;但不能切断杂交形成的双链DNA,因此可利用杂交保护的方法对单链DNA实行定位切断. The use of quartz crystal microbalance (QCM) for in-situ monitoring the immobilization of single-stranded DNA(oligo-1), marked with mercaptol group at 5′ end, on the surface of gold-filled 7.995 MHz AT-cut quartz crystal by Au-S bond with self-assemble technique is reported. And then the hybridization of ssDNA with the complementary 10-mer ODN(oligo-2) and 8-mer ODN(oligo-3) is described. Moreover, the QCM has been employed to analyze the DNA cleavage by cerium(IV) ions under moderate conditions. The results showed that the QCM, which is capable of sensitive measurement, was able to in-situ investigate immobilization, hybridization and cleavage of ssDNA. And the cerium(IV) ions had no cleavage for the double-stranded DNA, but it could hydrolyze single-stranded DNA. So the hydrolytic cleavage of ssDNA at the specific site could be realized by the protection of the hybridization.
出处 《电化学》 CAS CSCD 北大核心 2005年第1期32-36,共5页 Journal of Electrochemistry
关键词 自组装技术 石英晶体微天平 碱基序列 铈离子 水解切断作用 QCM方法 DNA 稀土金属 Quartz crystal microbalance, Qligodeoxynucleotide, Hybridization, Hydrolytic cleavage
  • 相关文献

参考文献14

  • 1Patolsky F, Lichtenstein A, Willner L, et al. A modified microgravimetric quartz-crystal microbalance assay of DNA using oligonucleotide functionalized lipo somes or biotinylate liposomes[J]. J. Am. Chem. Soc., 2002, 122:418~419.
  • 2Aberl F, Wolf H. HIV serology using piezoelectric immunosensors[J]. Sensors and Actuators B, 1994, 18~19: 271~275.
  • 3Zhou Xichun, Huang Liqun, Samfong Yaoyi. Microgravimetric DNA sensor based on quartz crystal microbalance:comparison of oligonucleotide immobilization methods and the application in genetic diagnosis[J]. Biosensor & Bioelectronics, 2001, 16: 85~91.
  • 4Mo Xiang-Tao, Zhou Yi-Ping, Lei Han, et al. Microbalance-DNA probe method for the detection of specific bacteria in water[J]. Enzyme and Microbial Technology, 2002, 30:583~589.
  • 5Yoshio Okahata, Kenichi Niikura, Yukio Sugiura,et al. Kinetic study of sequence-specific binding of GCN4-bZIPpeptides to DNA strands immobilized on a 27-MHz quartz crystal microbalance[J]. Biochemistr., 1998, 37:5 666~5 672.
  • 6沈鹤柏,夏静芬,杨海峰,骆玉美.Hydrolysis of oligodeoxynucleotide phosphodiester linkages[J].Science China Chemistry,2001,44(2):169-174. 被引量:4
  • 7Frank Caruso,Elke Rodda,Neil Furlong D,et al. Quartz crystal microbalance study of DNA immobilization and hybridization for nucleic acid sensor development[J]. Anal. chem., 1997,69:2 043~2 049.
  • 8Keiko Ito, Koji Hashimoto, Yoshio Ishimori. Quantitative analysis for solid-phase hybridization reaction and binding reaction of DNA binder to hybrids using a quartz crystal microbalance[J]. Analytica Chimica Acta, 1996, 327: 29~35.
  • 9Yoshio Okahata, Masanori Kawase, Kenichi Nikura, et al. Kinetic measurements of DNA hybridization on an oligonucleotide immobilized 27-MHz quartz crystal microbalance[J]. Anal.Chem.,1998, 70: 1 288~1 296.
  • 10Braham Ulman, Jung F Kang, Yitzhak Shnidman, et al. Self-assembled monolayers of rigid thiols[J]. Reviews in Molecular Biotechnology, 2000, 74:175~188.