期刊文献+

Adsorption and Step Elution of Urokinase Using Affinity Chromatography-Comparison of Data with Rate Model Simulation

Adsorption and Step Elution of Urokinase Using Affinity Chromatography-Comparison of Data with Rate Model Simulation
下载PDF
导出
摘要 A non-equilibrium chromatographic rate model was employed to simulate the affinity chromatography of urokinase. The chromatography process was developed to a yield of high purity product of urokinase from crude materials. The affinity gel used in the process was prepared by an epichlorohydrin-activation method using epichlorohydrin activated Sepharose 4B as a matrix and p-aminobenzamidine as a ligand. The chromatographic process were numerically simulated and analyzed with the aid of VERSE-LC computer simulator. Considering the basic principles, rate model with the back mixing in column inlet was utilized in simulating and studying the effect of the column inlet pattern on other parameters. Comparison of the simulation results with the experimental data showed that the rate model can be used to describe the affinity chromatography of urokinase in a fixed bed column with satisfactory accuracy. A non-equilibrium chromatographic rate model was employed to simulate the affinity chromatography of urokinase. The chromatography process was developed to a yield of high purity product of urokinase from crude materials. The affinity gel used in the process was prepared by an epichlorohydrin-activation method using epichlorohydrin activated Sepharose 4B as a matrix and p-aminobenzamidine as a ligand. The chromatographic process were numerically simulated and analyzed with the aid of VERSE-LC computer simulator. Considering the basic principles, rate model with the back mixing in column inlet was utilized in simulating and studying the effect of the column inlet pattern on other parameters. Comparison of the simulation results with the experimental data showed that the rate model can be used to describe the affinity chromatography of urokinase in a fixed bed column with satisfactory accuracy.
出处 《Chinese Journal of Biomedical Engineering(English Edition)》 2004年第4期166-178,共13页 中国生物医学工程学报(英文版)
关键词 尿激酶 套色版 吸附实验 天然原料 亲和力 模型 Rate model simulation, Affinity chromatography, Urokinase, Back mixing
  • 相关文献

参考文献10

  • 1JoukjeH,HugoAH,L uukAM,van derWielen. American Institute of Chemical Engineers Journal . 2003
  • 2WeiDC,XiaoYD,ShuB,YanS. Biochem Eng.J . 2003
  • 3KaczmarskiK,AntonsD,SajonzH,et al. Journal of Chromatography . 2001
  • 4SchneiderPh,BachmannF,SuserD. SeronoSymposiumNo.48 . 1982
  • 5HolmbergL,BladhB,AstedB. Biochimica et Biophysica Acta . 1976
  • 6CaoXJ,ZhuJW,WangDW,et al. ChineseJ.Chem.Eng . 1997
  • 7MaZ,WhitleyRD,Wang,N -H.L. AICHE Journal . 1996
  • 8.
  • 9WilsonEJ,GeankoplisCJ. Ind.Engng.Chem.Fundam . 1966
  • 10MackieJS,MearesP. Proc.R Soc.L ond.Ser.A . 1955

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部