摘要 通过比较双眼Bjerrum区平均光敏感度(MS),分析36名至少1眼有早或中期视野缺损的青光眼和42名正常人自动视野检查资料,应用自定的标准,获得80.6%(29/36)的敏感性和88.1%(37/42)的特异性。在青光眼组,较低MS眼多为较高眼压眼,在有不对称C/D值或相对性传入性瞳孔障碍者,较大青光眼杯或传入性瞳孔障碍眼MS恒低于对侧眼。 e analyzed the automated perimetry data from 36 glaucoma patients with early or moderate visual fielddefects at least in one eye and 42 normal subjects by comparing the mean sensitivity(MS)of both eyes,Usingour criteria,it yielded a sensitivity of 80.56%(29/36)and a specific of 88.10%(37/42).In the glaucomapatients, the MS was lower in the higher IOP eyes than in the lower IOP eyes.In the patients with optic discasymmetry or relative afferent pupillary defect,the MS was consistently lower in the eyes with the moreabnormal disc and in the eyes with afferent pupillary defect.
出处 《眼科研究》 CSCD 1994年第1期43-45,共3页 Chinese Ophthalmic Research
关键词 青光眼 视野缺损 不对称性损害 glaucoma,visual field defect,asymmetry,automated perimetry