本文研究了镓与水杨醛-2-并噻唑腙的荧光反应,确定了最佳反应条件。用荧光法测定了配合物的组成比为1:3,建立了测定微量镓的新荧光光度法。用此法测定合成样品中微量镓,其结果的准确度和精密度均较满意。
A new fluorescence reaetion of gallium with the salicylaldehyde-2-benzothiazolylhy-drazone has been investigated. The optimum conditions of the reaction are established.The molarratio of gnllium to salicylaldehyde-2-benzothiazolylhydrazone in the complex is 1:3.A new fluo-rimetric method for determination of the microamount gallium is established.The contents ofgallium in synthetic samples are analysed with satisfactory results.