摘要
分析了南京地区水文地质概况及水源热泵空调系统引用地下水时应注意的问题。同时利用建筑负荷特点与系统运行能耗两种手段 ,分析热源型式、气象条件、建筑特点等因素对系统运行经济性的影响。
Nanjing's hydrology and geology and its ine ff iciency of electricity in current situation were introduced.Questions should be paid attention to when groundwater is applied to Water source Heat Pump. Meanwhi le two means that are characteristic of architecture's load and energy's assumpt ion when system is in motion are used to analyse their influences to economical property when system is in motion. These influences are imposed by several facto rs that are heat source's type, atmosphere, architecture's characteristic.
出处
《流体机械》
CSCD
北大核心
2005年第3期67-69,共3页
Fluid Machinery
关键词
水源热泵(WSHP)
地下水
能耗
冷负荷数
Water Source Heat Pump
groundwater
energy's assumption
figure of cold load