摘要 污闪威胁到电力系统的安全运行。文章根据污秽放电伴随的超声信号,提出用声发射信号来反映绝缘子的污闪过程。进行了大量污秽试验,采集了绝缘子污秽放电时的声发射信号波形。分析结果表明声发射信号可以反映绝缘子污秽放电的强弱,因而可以实现绝缘子的污闪监测。 Contaminant flashover is one of the primary dangers to electric power systems. In this paper, the method which can judge the working condition of the insulator based on the acoustic emission is given (AE method). A lot of experiments are performed, the AE signals have been acquired in the AC contaminant experiment. The analysis shows that the signal wave can reflect the insulator flashover, so the working condition of the insulator can be monitored.
出处 《电力科学与工程》 2005年第1期32-35,共4页 Electric Power Science and Engineering
关键词 绝缘子 污秽放电 声发射信号 insulator acoustic emission signal contaminant flashover
  • 相关文献

参考文献3

  • 1LUNDGAARD L E.Acoustic partial discharge detectionpractical application [J]. IEEE Electrical Insulation Magzine, 1992, 8 (5): 34-43.
  • 2李明,舒乃秋,彭旭东,刘敏.基于声发射技术的绝缘子污秽放电监测[J].电力自动化设备,2004,24(6):98-100. 被引量:12
  • 3ABDEL-SALAM M. Early detection of weak point in MEEC distribution system [J]. IEEE, 2001, 2541 2545.

二级参考文献2

  • 1LUNDGAARD L E. Partial discharge. XIV. acoustic partial discharge detection-practical application[J]. IEEE Electrical Insulation Magzine, 1992,8 (5): 34- 43.
  • 2GUPTA N, RAMU T S. Estimation of partial discharge parameters in GIS using acoustic emission techniques[J].Journal of Sound and Vibration,2001,247(2):243-260.