期刊文献+

Third Generation Horseradish Peroxidase Biosensor Based on Self-assembling Carbon Nanotubes to Gold Electrode Surface

Third Generation Horseradish Peroxidase Biosensor Based on Self-assembling Carbon Nanotubes to Gold Electrode Surface
下载PDF
导出
摘要 A third-generation horseradish peroxidase (HRP) biosensor has been developed by adsorbing HRP on multi-wall carbon nanotube (MWNTs) monolayer modified gold electrode surface. The assembly process was investigated by electrochemical and spectroscopic techniques. Results showed that the immobilized HRP exhibited direct electrochemical behavior toward the reduction of H2O2. The resulting biosensor shows a fast amperometric response (<2 s) to H2O2. The linear response range was from 5.0×10-7~1.0×10-5 mol/L with a detection limit of 1.0×10-7mol/L. Moreover, the biosensor has a good reproducibility, and long-term stability. A third-generation horseradish peroxidase (HRP) biosensor has been developed by adsorbing HRP on multi-wall carbon nanotube (MWNTs) monolayer modified gold electrode surface. The assembly process was investigated by electrochemical and spectroscopic techniques. Results showed that the immobilized HRP exhibited direct electrochemical behavior toward the reduction of H2O2. The resulting biosensor shows a fast amperometric response (<2 s) to H2O2. The linear response range was from 5.0×10-7~1.0×10-5 mol/L with a detection limit of 1.0×10-7mol/L. Moreover, the biosensor has a good reproducibility, and long-term stability.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第4期523-526,共4页 中国化学快报(英文版)
关键词 Horseradish peroxidase MWNT self-assembly third-generation biosensor. Horseradish peroxidase, MWNT, self-assembly, third-generation biosensor.
  • 相关文献

参考文献13

  • 1S. Iijima, Nature, 1991, 354, 56.
  • 2P.J. Britto, K. S. V. Santhanam, P. M. Ajayan, Biosens. Bioelectron., 1996, 41, 121.
  • 3H. Luo, Z. Shi, N. Li, Z. Gu, Q. Zhuang, Anal. Chem.,2001,73,915.
  • 4R.J. Chen, Y. Zhang, D. Wang, H. Dai, J. Am. Chem. Soc., 2001, 123, 3838.
  • 5A. Guiseppi-Elie, C. H. Lei, R. H. Baughman, Nanotechnology, 2002, 13, 559.
  • 6J. Wang, M. Musameh, Anal. Chem., 2003, 75, 2075.
  • 7Y.D. Zhao, W. D. Zhang, H. Chen, Q. M. Luo, Anal. Sci., 2002, 18, 939.
  • 8S. Sotiropoulou, N. A. Chaniotakis, Anal. Bioanal. Chem., 2003, 375, 103.
  • 9Y.D. Zhao, W. D. Zhang, H. Chen, Q.M. Luo, S. F. Y. Li, Sens. and Actuat. B, 2002, 87, 168.
  • 10J.Z. Xu, J. J. Zhu, Q. Wu, Z. Hu, H. Y. Chen, Electroanalysis, 2003, 15, 219.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部