CR-39固体核径迹探测器用于中子测量化学蚀刻参数的优化 被引量:8

Optimum condition of chemical etching of CR-39 solid state nuclear track detector for neutron measurement
下载PDF
导出
摘要 通过实验确定了CR-39固体核径迹探测器用于中子测量的化学蚀刻条件。根据有关资料和经验,对蚀刻结果影响较大的三个因子——蚀刻溶液的浓度(mol/L)、温度(℃)和蚀刻时间(h),采用正交试验法,并对正交试验进行补充和验证;通过对实验结果综合分析比较,在NaOH溶液浓度为5.5mol/L、温度70℃和时间24h的蚀刻条件下,CR-39固体核径迹探测器对中子所形成的径迹轮廓清晰、大小适度,蚀刻效率高,易于识别和测读,能满足中子测量的需要。 The chemical etching condition of CR-39 solid state nuclear track detector for neutron measurement was optimized by experiment. According to the literature and experience, three factors, i.e. solution concentration, etching time and etching temperature, mainly affect the etching results and have been tested by orthogonal design. A series of experiments were followed to reinforce and verify the orthogonal design. It is shown that under the etching condition of 5.5 mol/L NaOH-70°C-24 h the nuclear tracks generated by neutrons on CR-39 solid state nuclear track detector can be etched at best etching efficiency. The tracks have clear profile and appropriate size, and are therefore easy to be identified.
出处 《核技术》 EI CAS CSCD 北大核心 2005年第4期319-323,共5页 Nuclear Techniques
关键词 CR-39固体核径迹探测器 正交试验 化学蚀刻 径迹 CR-39 solid state nuclear track detector, Orthogonal design, Chemical etching, Track
  • 相关文献

参考文献3

二级参考文献3

共引文献31

同被引文献64

  • 1张贵英,倪邦发,李丽,田伟之,王平生,黄东辉,张兰芝,刘存兄,刘立坤,李德红.利用核径迹技术研制个人中子剂量气泡探测器[J].核技术,2005,28(9):663-666. 被引量:5
  • 2刘瑛,魏功.异常值检测中GRUBBS法的改进[J].河南科学,2006,24(5):641-644. 被引量:6
  • 3李景云.中子反照率个人剂量计[J].辐射防护通讯,1996,16(3):1-8. 被引量:2
  • 4陈魁.试验设计与分析[M].北京:清华大学出版社,2005:72—138.
  • 5Ipe N E, Liu J C, Buddemeier B R, et al. A comparison of the neutron response of CR-39 made by different manufacturers[J]. Radiation Protection Dosimetry, 1992, 44(1-4), 317-321.
  • 6Mishra R, Orlando C, Tommasino L, et al. A better understanding of the background of CR-39 detectors[J]. Radiation Measurements, 2005, 40 (2-6):325-328.
  • 7Mosier-Boss P A, Szpak S, Gordon F E, et al. Characterization of tracks in CR-39 detectors obtained as a result of Pd/D Co-deposition[J]. The European Physical Journal Applied Physics, 2009, 46(3): 30901.
  • 8许伟,李天柁,马文彦,等.固体核径迹探测器最佳蚀刻条件选择[C].第十二届全国核电子学与核探测技术学术年会论文集,昆明,2004.
  • 9Basma A, Badry E, Zaki M F, et al. An optical method for fast neutron dosimetry using CR-39[J]. Radiation Effects and Defects in Solids, 2008, 163(10):821-825.
  • 10Kumar Vijay, Sonkawad R G, Dhaliwal A S. Optimization of CR-39 as neutron dosimeter[J]. Indian Journal of Pure & Applied Physics, 2010,48(7):466-469.