高层楼供水泵房动态设计研究

Research on Dynamic Design Approach in the Pump Room of Water Supply System to High Buildings
下载PDF
导出
摘要 讨论了高层楼供水泵房问题.从减小液体压力脉动与传递、减小泵自身振动与传递两个方面对其结构进行动态设计研究;并采取了隔振、添加软连接、缓冲器等减振降噪措施,有效地降低了振动和噪声,达到了环保标准。 Discuss the noise problem of pump room in high buildings. The dynamic design approach to its structure is studied by two aspects, one is how to reduce the pressure fluctuation and its transmission, the other is how to reduce the vibration of pump and its transmission; Some measures are adopted such as vibration isolation,flexible connection and buffer, to decline the vibration and noise. The result meets the standards of environmental protection.
出处 《天津科技大学学报》 CAS 2005年第1期49-51,共3页 Journal of Tianjin University of Science & Technology
基金 天津市高等学校科技发展基金资助项目(020501)
关键词 泵房 压力脉动 缓冲器 隔振 pump-room pressure fluctuation buffer vibration isolation