摘要
研究了重铬酸钾(银)剂量计的剂量学性能。确定了重铬酸钾溶液在440nm下的线性摩尔吸收系数为46.52m ̄2·mol ̄(-1);剂量计辐照温度系数为-0.22%/℃;G()值为3.91×10 ̄(-8)mol·J ̄(-1);剂量转换因子为5.74×10 ̄4Gy。测量总不确定度为±4%(2σ)。
The dosimetry of potassium dichromate dosimeter is investigated.The linear molar ab-sorbance coefficient at 440 nm of potassium dichromate solution is determined being 46.52m ̄2/moland the temperature coefficient of the dosimeter during irradiation is-0.22%/℃, The measuredG value,dose-absorbance conversion factor are 3 91 ×10 ̄(-8)mol /J and 5.74 ×10 ̄4 Gy,respectively,The total unceriainty estimated as 4% (95% confidence).
出处
《原子能科学技术》
EI
CAS
CSCD
北大核心
1994年第3期284-288,共5页
Atomic Energy Science and Technology
关键词
重铬酸钾
剂量计
吸收剂量
Potassium dichromate Dosimeter Absorbed dose