采用DPASV法测定金属Na中的痕量元素Cd。以正交试验法确定最佳仪器条件。试样可不经分离在pH2NaNO_3溶液中直接测定Cd。其检测下限达0.02ng/ml。测得值的相对标准偏差为12%。
The trace cadmium in sodium metal is determinated with DPASV, and the best parametersof the polarograph for this test is found with orthogonal experimental method. The cadmium insodium is deterinined directly in NaNO_3 .colution of PH2. The lower limit of the deterznination forCd is to 0. 02 ng/ml. The method can be used to deterniinate ω ( Cd) = 10-6-10-9 in sodiummetal, and the relative standard deviation is 12% .