期刊文献+

锅炉汽包差压水位计测量误差分析及处理 被引量:1

Treatment Method and Analyzing of Measure Tolerance about Drum Differential Pressure Water Level Gauge of Boiler
下载PDF
导出
摘要 针对汽包差压水位计测量误差大使汽包水位自动及保护装置不能正常投用问题,对引起测量误差的机理进行探讨。分析认为测量装置取样不合理及平衡容器水温未进行修正是测量误差大的主要原因,并提出处理的对策。减小了汽包差压水位计测量误差。 The defects that the measure error of drum differential pressure water level gauge can't put the equipment of automation and protection into use normally,after analyzing the mechanism of measure error,The author believe that there are two main reasons,one is irrational sampling of equipment,the other is that temperature of water in the container is not corrected properly,and also brings up a treatment suggestion.The measure error of drum differential pressure water level gauge is reduced now.
作者 秦德华
机构地区 云浮发电厂
出处 《电力勘测设计》 2004年第3期56-58,共3页 Electric Power Survey & Design
关键词 锅炉 汽包差压水位计 测量误差 boiler drum differential pressure water level gauge measure error
  • 相关文献

参考文献2

  • 1吴永生.热工测量及仪表.北京:中国电力出版社,1998
  • 2饶纪杭.锅炉差压水位表使用中的几个问题[J].东方自动化,2002,(10).