摘要 以水为工作介质,研究了降膜蒸发管内插入螺旋线对蒸发侧传热性能的影响,对8种不同参数的螺旋线进行了恒壁温实验.结果表明,采用插头式布膜器在雷诺数为4 000~14 000范围内较溢流型布膜器可提高传热系数.同时讨论了传热温差、雷诺数、螺旋线结构参数和真空度对降膜侧传热性能的影响.并在此次实验的基础上提出了最佳螺旋线参数的范围. The influence of the falling film evaporating tubes inserted helixes on the heat transfer of evaporation side was studied taking water as a medium. A constant wall temperature experiment was made for the helixes of eight different parameters. The result shows that the heat transfer coefficient could be raised by using the interposition distributor than using the overflow distributor when Reynold number was between 4 000~14 000. Meanwhile, the influences of temperature difference of heat transfer, Reynold number, structure parameters of helixes, and vacuum degree on the heat transfer performance of falling film side were discussed, and the best range of helix parameter was proposed based on the experiment.
出处 《化工机械》 CAS 2005年第2期72-77,共6页 Chemical Engineering & Machinery
关键词 降膜蒸发器 传热强化 螺旋线插入物 传热系数 Falling Film Evaporator, Heat Transfer Intensification, Helix Insert, Heat Transfer Coefficient
  • 相关文献

参考文献5

二级参考文献3

  • 1孙长贵,于志加,丁洁,徐维勤,沈自求.两相流载气蒸发研究和传热数据关联[J]化工学报,1988(06).
  • 2于志加,徐维勤,丁洁,沈自求.载气蒸发传热及其流型的研究[J]高校化学工程学报,1987(02).