摘要
针对某厂丁二烯螺杆压缩机运行存在因泄漏严重导致检修频繁的问题,从设计、制造、操作、检修等方面对泄漏的原因进行分析,提出了多项改造意见,通过实施收到良好效果。
The leak causes were analyzed and some retrofit suggestions were proposed for screw compressors for butadiene in design, fabrication, operations, and maintenance for the frequent repairs induced with serious leak, and a good result was obtained after the retrofit.
出处
《化工机械》
CAS
2005年第2期113-116,共4页
Chemical Engineering & Machinery
关键词
螺杆压缩机
泄漏分析
丁二烯
双列螺旋槽油膜端面机械密封
改造
Screw Compressor, Leak Analysis, Butadiene,Spiral Groove Oil Film End Face Machinery Seal, Retrofit