期刊文献+

断续螺旋折流板在管壳式换热器中的应用 被引量:12

Application of discontinuous helical baffles in shell-and-tube heat exchanger
下载PDF
导出
摘要 对断续螺旋折流板与普通弓形折流板管壳式换热器的传热与流阻特性进行了实验对比研究.研究结果表明:将断续螺旋折流板应用于管壳式换热器能明显增强换热效果,在相同流速下壳侧换热系数是弓形折流板换热器的1.39~1.67倍,断续螺旋折流板换热器的总传热系数是弓形折流板换热器的1.15~1.37倍;但阻力有所增加,壳侧阻力是单弓形折流板换热器的3.25~3.67倍. Experimental investigations of heat transfer and flow resistance performance on shell-and-tube heat exchanger with smooth tubes supported by different kinds of baffles are carried out. Discontinuous helical baffles and segment baffles are used in the experiments and their performances are compared. The experimental results show that applying discontinuous helical baffles in shell-and-tube heat exchanger can enhance the heat transfer apparently. Under the same liquid velocity condition, the average convection heat transfer coefficient in the shell side of discontinuous helical baffles shell-and-tube heat exchanger is 1.39~1.67 times compared with that in the shell side of segment baffles shell-and-tube heat exchanger ,and the total average convection heat transfer coefficient is 1.15~1.37 times. But it makes flow resistance increase,and the flow resistance in the shell side is 3.25~3.67 times compared with that in the shell side of segment baffles shell-and-tube heat exchanger.
出处 《应用科技》 CAS 2005年第4期45-47,共3页 Applied Science and Technology
关键词 断续螺旋折流板 管壳式换热器 强化换热 水工质 discontinuous helical baffles shell-and-tube heat exchanger heat transfer enhancement water
  • 相关文献

参考文献2

共引文献51

同被引文献90

引证文献12

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部